2.6.2 Switching on or switching off the pass-through mode
The pass-through mode is required if communication is required with the SMART sensor
connected to the HMG directly from your PC.
Click on "Pass-through mode" in the interface settings window.
If it is possible to switch the pass-through mode both on or off at one port (or at
more than one), a new window opens to switch the pass-through mode on or off.
In the dropdown menu select the port connected to the SMART sensor for which
you wish to switch the pass-through mode on or off.
Click on "Switch on" to switch on the pass-through mode for the selected port or
on "Switch off" to switch off the pass-through mode for the selected port.
An information window opens which you must confirm with "OK".
2.6.3 Switching on or switching off the multisensor mode
The multisensor mode is required if several sensors with a clearly allocated bus address are
connected to the same interface.
Click on the box in front of "Multisensor mode“ to activate or deactivate the
multisensor mode.
The bus address can be set by clicking "Set bus address".
After estabishing a link with the SMART sensor you can change the bus address of
the sensor by clicking on "Set bus address“ on the left side of the main window.
In both cases select the required setting in the dropdown menu.
Important: in the multisensor mode some functions are restricted.